Skip to main content

Monitor unit (MU)  is a crucial parameter in radiation therapy that helps to determine the amount of radiation to be delivered to the patient during treatment. This value is critical for the safe and effective delivery of radiation therapy. The monitor unit verification is a complex process that involves the use of algorithms to determine the appropriate amount of radiation to be delivered.

There are various standards that govern the calculation of monitor units in radiation therapy, including AAPM TG 71, AAPM TG 114, and AAPM TG 219. These standards provide guidelines and recommendations on how to perform the calculation and how to verify its accuracy.

There are several algorithms used to calculate monitor units, including Clarkson, Modified Clarkson, Monte Carlo, Collapsed Cone Convolution/Superposition, and Three-Source Model. Each of these algorithms has its own advantages and disadvantages and is used depending on the specific requirements of the treatment.

The Clarkson algorithm is one of the simplest and most widely used algorithms for monitor unit calculation. It is based on the principle of superposition, where the dose from each radiation field is added together to obtain the total dose. The Modified Clarkson algorithm is an improvement over the Clarkson algorithm and takes into account the effects of scatter radiation. The Monte Carlo algorithm is based on computer simulations and is considered the most accurate method for monitor unit calculation. The Collapsed Cone Convolution/Superposition and Three-Source Model algorithms are also commonly used in radiation therapy and offer different advantages in specific treatment scenarios.

Second Check Software

It is important to use secondary check software to calculate monitor units, as it provides a quick and accurate method to verify the calculations. This use of secondary software brings agility to the medical physics team and ensures patient safety by providing a quick and efficient method of verifying the accuracy of the monitor unit calculation.

Second Check Verification - Monitor Unit Calculation

Second Check Verification – Monitor Unit Calculation

The RT Connect Software is an example of a cloud software that performs monitor unit calculations. This software brings agility to the medical physics team by providing a cloud-based solution that can be accessed from anywhere with an internet connection. This allows medical physicists to perform the monitor unit calculation quickly and easily, without the need for specialized software or hardware.

RT Connect is a cloud system for Second Check Verification

 

Monitor unit calculation is a critical aspect of radiation therapy that requires a precise and accurate calculation. The use of second check software, such as RT Connect Software, helps to bring agility to the medical physics team and ensures patient safety. By using the most appropriate algorithm and adhering to the guidelines provided by AAPM TG 71, AAPM TG 114, and AAPM TG 219, medical physicists can deliver safe and effective radiation therapy to their patients.

 

Example of software searching the PACS for DICOM RT files to perform the second check