{"id":19905,"date":"2026-10-19T05:23:41","date_gmt":"2026-10-19T08:23:41","guid":{"rendered":"https:\/\/rtmedical.com.br\/tmp-en-1792398221325\/"},"modified":"2026-10-19T05:23:48","modified_gmt":"2026-10-19T08:23:48","slug":"total-body-pet-one-minute","status":"publish","type":"post","link":"https:\/\/rtmedical.com.br\/en\/total-body-pet-one-minute\/","title":{"rendered":"Total-Body PET Delivers Usable Images in 1 Minute"},"content":{"rendered":"<h2>A one-minute scan beat the standard-of-care exam<\/h2>\n<p>A long-axial-field-of-view PET\/CT produced diagnostic-quality images from just one minute of<br \/>\nacquisition \u2014 and even at that extreme the readers scored it above the conventional PET\/CT used in<br \/>\ndaily practice. The result was presented on October 18 at the annual meeting of the European<br \/>\nAssociation of Nuclear Medicine (EANM) in Vienna by Cameron Pain, of the Peter MacCallum Cancer<br \/>\nCentre in Melbourne, Australia.<\/p>\n<p>&#8220;A one-minute scan on this system gave us images that our readers rated more highly than the<br \/>\nstandard-of-care scans we perform every day,&#8221; Pain said in an EANM news release. &#8220;That was the<br \/>\nstriking finding: even when we cut the acquisition time by 90%, image quality exceeded current<br \/>\nstandard-of-care methods.&#8221;<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" class=\"alignleft lazyload\" data-src=\"https:\/\/rtmedical.com.br\/wp-content\/uploads\/2026\/10\/total-body-pet-acquisition-time-image-quality.png\" alt=\"Bar chart comparing total-body PET diagnostic quality scores at 10, 5, 3, 2 and 1 minute against conventional PET\/CT\" width=\"640\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 1200px; --smush-placeholder-aspect-ratio: 1200\/630;\"><figcaption>Mean diagnostic quality score (1 to 5) by acquisition time, against conventional PET\/CT.<\/figcaption><\/figure>\n<h2>How the study was built<\/h2>\n<p>Twenty-four patients scheduled for oncological PET\/CT took part, each receiving one of five<br \/>\nradiotracers. Every participant had a standard-of-care scan on a conventional short-axial-field-of-view<br \/>\n(SA-FOV) system and, immediately afterwards, a 10-minute acquisition on the long-axial-field-of-view<br \/>\n(LA-FOV) Omni Legend 128 from GE HealthCare \u2014 a scanner with a 128 cm axial field of view that<br \/>\ncovers essentially the whole body in a single bed position.<\/p>\n<p>From the raw data of that single 10-minute acquisition, the researchers reconstructed images<br \/>\nequivalent to 5, 3, 2 and 1 minute of counting time. Two nuclear medicine specialists, blinded to<br \/>\nacquisition time, graded each set on a five-point scale for overall diagnostic quality, sharpness,<br \/>\nlesion conspicuity (how clearly a lesion stands out from surrounding tissue) and image noise.<\/p>\n<h2>The numbers behind the headline<\/h2>\n<p>Mean diagnostic quality scores were 5.0 for the 10- and 5-minute reconstructions, 4.9 for the<br \/>\n3- and 2-minute reconstructions and 4.5 for the 1-minute set. Conventional PET\/CT scored 3.9 and<br \/>\nposted lower averages than the LA-FOV system across every assessed category and every acquisition<br \/>\ntime. Put plainly: the most aggressive reconstruction on the new scanner still read better than a<br \/>\nfull-length exam on the old one.<\/p>\n<p>It is worth saying why that is physically plausible. A PET scanner detects annihilation photon<br \/>\npairs in coincidence; the longer the axial field, the larger the solid angle covered and the greater<br \/>\nthe fraction of emitted events that actually reaches the detectors. A 128 cm system captures roughly<br \/>\nan order of magnitude more counts per unit time than a 20 to 25 cm one. Because signal-to-noise in<br \/>\nPET scales approximately with $\\sqrt{N}$, where $N$ is the number of acquired counts, that<br \/>\nsensitivity gain can be spent on time, on dose or on image quality \u2014 which is exactly the author&#8217;s<br \/>\nargument.<\/p>\n<h2>Three currencies, one sensitivity gain<\/h2>\n<p>&#8220;Total-body PET gives us choices we haven&#8217;t had before. We can use its sensitivity to scan<br \/>\npatients faster, to lower the radiation dose and to see disease more clearly,&#8221; Pain said. That is<br \/>\nthe right reading: the gain is singular and has to be allocated.<\/p>\n<p>Shorter scans affect comfort directly, especially for patients in pain or unable to lie still,<br \/>\nand they cut motion blurring \u2014 a problem we examined when we looked at<br \/>\n<a href=\"https:\/\/rtmedical.com.br\/en\/mri-repeat-sequences-motion-cost\/\">the cost of motion-related repeat sequences in MRI<\/a>.<br \/>\nThey also raise daily throughput and, through higher sensitivity, allow less radiotracer per<br \/>\npatient, which matters economically in departments that depend on short-half-life<br \/>\nradiopharmaceuticals.<\/p>\n<h2>What it means for practice and for the installed base<\/h2>\n<p>No department replaces a PET\/CT on the strength of a conference abstract, but the replacement<br \/>\nconversation shifts when the argument stops being &#8220;nicer images&#8221; and becomes installed capacity. If<br \/>\none scanner does in 2 minutes what another does in 20, the return calculation no longer hinges on<br \/>\npurchase price alone: throughput per shift, tracer consumption and the ability to scan patients who<br \/>\ncannot tolerate a long protocol all enter the equation.<\/p>\n<p>There is a rarely mentioned counterweight. Very short protocols increase departmental load in<br \/>\neverything that is not acquisition \u2014 preparation, venous access, uptake time, positioning and<br \/>\nreporting \u2014 and those steps do not shrink proportionally. The bottleneck tends to migrate from the<br \/>\nscanner room to the schedule. LA-FOV systems also generate larger data volumes per study, with<br \/>\ndirect consequences for storage and network, a point we raised when analysing<br \/>\n<a href=\"https:\/\/rtmedical.com.br\/en\/yale-new-haven-pet-mri-connecticut\/\">high-cost hybrid scanner installations<\/a>.<\/p>\n<h2>The limits of what was shown<\/h2>\n<p>The author himself drew the boundaries. This is 24 patients, with a subjective reading endpoint<br \/>\nrather than diagnostic accuracy measured against a reference standard. Larger studies will need to<br \/>\nconfirm that very short acquisitions do not miss small or faint lesions \u2014 the scenario where<br \/>\nreduced counts should hurt most. And it remains to be seen how fast scanning behaves in real<br \/>\nworkflow: scheduling, tracer logistics and patient experience do not show up in an image quality<br \/>\nscore.<\/p>\n<p>Even so, the direction is consistent with what other groups have reported since the first<br \/>\nlong-axial-field systems arrived. The debate is no longer whether the extra sensitivity exists, but<br \/>\nhow to spend it \u2014 on speed, on dose or on detection. For anyone following<br \/>\n<a href=\"https:\/\/rtmedical.com.br\/en\/psma-pet-biopsy-negative-mri\/\">the growing use of PET in targeted diagnostic pathways<\/a>,<br \/>\nit is a choice that will keep surfacing in protocol design.<\/p>\n<p><strong>Source:<\/strong> <a href=\"https:\/\/www.auntminnie.com\/clinical-news\/molecular-imaging\/article\/15837735\/eanm-nextgeneration-pet-scanner-cuts-imaging-time-to-one-minute\" target=\"_blank\" rel=\"noopener\">AuntMinnie \u2014 EANM: Next-generation PET scanner cuts imaging time to one minute<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>At EANM 2026, long-axial-field PET produced diagnostic images in one minute and outscored conventional PET\/CT. See the numbers and the limits.<\/p>\n","protected":false},"author":5,"featured_media":19860,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"ngg_post_thumbnail":0,"_rt_cluster":"","fifu_image_url":"","fifu_image_alt":"","footnotes":""},"categories":[100],"tags":[],"class_list":["post-19905","post","type-post","status-publish","format-standard","has-post-thumbnail","category-radiology"],"aioseo_notices":[],"rt_seo":{"title":"","description":"At EANM 2026, long-axial-field PET produced diagnostic images in one minute and outscored conventional PET\/CT. See the numbers and the limits.","canonical":"","og_image":"","robots":"index,follow","schema_type":"Article","include_in_llms":true,"llms_label":"Total-body PET in one minute (EANM 2026)","llms_summary":"A study presented at EANM 2026 showed a long-axial-field-of-view PET\/CT producing diagnostic-quality images from one minute of acquisition, scoring 4.5 versus 3.9 for conventional PET\/CT in 24 oncology patients.","faq_items":[],"video":[],"gtin":"","mpn":"","brand":"","aggregate_rating":[]},"_links":{"self":[{"href":"https:\/\/rtmedical.com.br\/en\/wp-json\/wp\/v2\/posts\/19905\/"}],"collection":[{"href":"https:\/\/rtmedical.com.br\/en\/wp-json\/wp\/v2\/posts\/"}],"about":[{"href":"https:\/\/rtmedical.com.br\/en\/wp-json\/wp\/v2\/types\/post\/"}],"author":[{"embeddable":true,"href":"https:\/\/rtmedical.com.br\/en\/wp-json\/wp\/v2\/users\/5\/"}],"replies":[{"embeddable":true,"href":"https:\/\/rtmedical.com.br\/en\/wp-json\/wp\/v2\/comments\/?post=19905"}],"version-history":[{"count":1,"href":"https:\/\/rtmedical.com.br\/en\/wp-json\/wp\/v2\/posts\/19905\/revisions\/"}],"predecessor-version":[{"id":19907,"href":"https:\/\/rtmedical.com.br\/en\/wp-json\/wp\/v2\/posts\/19905\/revisions\/19907\/"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/rtmedical.com.br\/en\/wp-json\/wp\/v2\/media\/19860\/"}],"wp:attachment":[{"href":"https:\/\/rtmedical.com.br\/en\/wp-json\/wp\/v2\/media\/?parent=19905"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/rtmedical.com.br\/en\/wp-json\/wp\/v2\/categories\/?post=19905"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/rtmedical.com.br\/en\/wp-json\/wp\/v2\/tags\/?post=19905"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}